Model | Thickness Range |
Wavelength Range | Standard Spot Size | |
---|---|---|---|---|---|
F3 | Reflectance and film-thickness measurements Features: Compact, low-cost, non-UV systems have 40k-hour light source. * Thickness measurement capability is optional. | ||||
![]() |
F3-NIR | 0.1-250 µm * | 950-1700 nm | 100 μm | |
F3-XT | 0.2-450 µm * | 1440-1690 nm | 100 μm | ||
F3-s980 | 10-1000 µm * | 960-1000 nm | 10 μm | ||
F10-AR | Reflectance measurement of large flat or curved samples Features: Handheld probe for large samples and maximum versatility. * Thickness measurement capability is optional. | ||||
![]() |
F10-AR-NIR | 0.5-30 µm * | 950-1700 nm | 100 μm |
Single-Spot Measurements |
Model | Thickness Range |
Wavelength Range | Standard Spot Size | |
---|---|---|---|---|---|
F10-RT | Reflectance and/or transmittance measurement Features: Simultaneous measurement of R and T. Built-in video. * Thickness measurement capability is optional. | ||||
![]() |
F10-RT-NIR | 0.1-150 µm * | 950-1700 nm | 5000 μm | |
F20 | The world's best-selling thin-film measurement system Features: Our most versatile model. Includes full thickness and index measurement capabilities. | ||||
![]() |
F20-NIR | 0.1-250 µm | 950-1700 nm | 1500 μm | |
F20-XT | 0.2-450 µm | 1440-1690 nm | 1500 μm | ||
F40 | Microscope-based thin-film measurement system Features: Attach to a microscope. Very small spot size. | ||||
![]() |
F40-NIR | 0.04-40 µm | 950-1700 nm | 1 μm |
In-line Measurements |
Model | Thickness Range |
Wavelength Range | Standard Spot Size | |
---|---|---|---|---|---|
F30 | Complete in-line thickness monitor Features: Optional high-speed photodiode detectors. | ||||
![]() |
F30-NIR | 0.1-250 µm | 950-1700 nm | 1500 μm | |
F30-XT | 0.2-450 µm | 1440-1690 nm | 1500 μm | ||
F32 | Compact solution for in-line measurements Features: Includes spectrometer(s), software, and 10k-hour light source. | ||||
![]() |
F32-NIR | 0.1-250 µm | 950-1700 nm | 1500 μm | |
F32-XT | 0.2-450 µm | 1440-1690 nm | 1500 μm | ||
F32-s980 | 10-1000 µm * | 960-1000 nm | 10 μm |
Multi-Point Mapping | Model | Thickness Range |
Wavelength Range | Standard Spot Size | |
---|---|---|---|---|---|
F50 | Measures thickness etc. at two points/second Features: Sample chucks (up to 300mm) sold separately. | ||||
![]() |
F50-NIR | 0.1-250 µm | 950-1700 nm | 1500 μm | |
F50-XT | 0.2-450 µm | 1440-1690 nm | 1500 μm | ||
F50-s980 | 4-1000 µm | 960-1000 nm | 10 μm | ||
F50-s1310 | 7-2000 µm | 1280-1340 nm | 10 μm | ||
F50-s1550 | 10-3000 µm | 1520-1580 nm | 10 μm | ||
F50-450 | Measures thickness on 450mm wafers Features: Sample chucks (up to 450mm) sold separately. | ||||
![]() |
F50-450-NIR | 0.1-250 µm | 950-1700 nm | 1500 μm | |
F50-XY | Measures thickness on large panels Features: LCD panels are a common application. | ||||
![]() |
F50-XY-NIR | 0.1-250 µm | 950-1700 nm | 1500 μm | |
F50-XY-XT | 0.2-450 µm | 1440-1690 nm | 1500 μm | ||
F54 | Automated film thickness mapping Features: Sample chucks (up to 450mm) sold separately. | ||||
![]() |
F54-NIR | 0.04-100 µm | 950-1700 nm | 7 μm | |
F60-t | Production-oriented film thickness mapping Features: Includes notch-finding, on-board baselining, and safety interlock. | ||||
![]() |
F60-t-NIR | 0.1-250 µm | 950-1700 nm | 1500 μm | |
F60-t-XT | 0.2-450 µm | 1440-1690 nm | 1500 μm | ||
F60-t-s980 | 4-1000 µm | 960-1000 nm | 10 μm | ||
F60-t-s1310 | 7-2000 µm | 1280-1340 nm | 10 μm | ||
F60-t-s1550 | 10-3000 µm | 1520-1580 nm | 10 μm |